GE Fanuc 6T Error List
CodeError Description
000Re-Apply the power after the parameter was input. (Parameter number 012 - 015, 018, 027, 028, 031, 032, 082, 083, 086, 087, 090, 124, 125, 128, 129, 316)
001TH alarm (a character with incorrect parity was input in the significant information zone).Correct the tape.
002TV alarm (The number of characters in a block is odd). This alarm will be generated when the TV check is effective. Correct the tape.
003Data exceeding the maximum allowable number of digits was input. (Refer to the item of maximum programmable dimensions.)
004A numeral, the sign (-) or decimal point was input without an address at the beginnimng of a block.
005The address was not followed by the appropriate data, but was followed by another address or EOB code.
006Sign "-" input error (Sign "-" was input after an address with which it can't be used, or two or more "-" signs were input.
007Decimal point "." input error (A decimal point was input after an address with which it can't be used, or two or more decimal points were input.
008The tape readerontrol switch is set to other than AUTO (without reel) or REEL ON, OFF (with reel).
009Unusable character was input in the significant information zone (B, C, Y, V, J or H)
010An unusable G Code was commanded. This alarm is generated also when a G Code with which the control is not equipped as an option is commanded.)
011Feedrate was not commanded at cutting feed or the feedrate was inadequate.
012E Code was commanded in the NC which does not have the E Code option.
014Lead increment/decrement value by addres K exceeded maximum command value or minus was commanded in a variable lead thread cutting.
022In circular interpolation command, radius designation was performed in the NC which is not equipped with the radius designation option.
023In circular interpolation command by radius designation, zero or negative value was commanded for address R.
030The tool offset number is too large for the T function.
031In the offset value input command (G10) or user macro input command, neumerical value under the address P specifying an offset number is too large or P is missed.
032In the offset value input command (G10) or user macro input command, specified offset value is too large.
033An intersecting point can not be determined in intersecting point calculation for tool nose radius compensation.
034The start up of cancel is going to be done in the G02 or G03 mode under the tool nose radius compensation.
035Skip cutting (G31) is specified during cutter compensation.
038Overcutting will occur in tool nose radius compensation because the arc start point or end point coincides with the arc center.
039Chamfering or corner R was commanded together with a start-up, a cancel, or switching between G41 and G42 in tool nose radius compensation. The program may cause overcutting to occur in chamfering or corner R.
040Overcutting will occur in tool nose radius compensation under a canned cycle G90 (G77) or G94 (G79)
041Overcutting will occur in tool nose radius compensation.
047One of G27 to G30 was commanded for the axis which has no reference point.
048A G30 was commanded without performing reference point return after the power was turned on or emergency stop.
A move command was executed without performing reference point return after the power was turned on or after an emergency stop in an NC which includes optional stored stroke limit.
050The chamfering or a corner R was commanded in a block which includes a thread cutting command.
051The block after a block containing a chamfering or a corner R was not a G01 command.
052The move direction or the move amount in the block following chamfering or a corner R command was not adequate.
053Two or more of I, K and R were commanded in a block in the chamfering or corner R command.
054The block in which the chamfering or the corner R was commanded includes a taper command.
055The move distance in the block which includes the chamfering or the corner R is smaller than the chamfering or the corner R.
056The addresses X (or Z) and I (or K) were commanded together in the block which includes the chamfering command.
G01 X(U)_____ I_____ ; or
G01 Z(W)_____ K_____ ;
059A selected work number program can not be found. (External work number selection function A)
060Commanded sequence number was not found in the sequence number search.
061Either address P or Q was not commanded in the block which includes a G70, G71, G72 or G73 command.
062
  • The number following address D in the block which includes a G71, G72 or G73 command was not positive.
  • The number following address K or D in the block which includes a G76 command was not positive. The number following address A in the block which includes a G76 command was not a usable number.
  • The number following address I, K or D in the block which includes a G74 or G75 command was negative. The address X was commanded in spite of the numeral following address I being zero or the address Z was commanded in spite of the numeral following address K being zero in the block which includes a G74 or G75 command.
063The sequence number which was specified by address P or Q in the block which includes a G70, G71, G72 or G73 command was not found.
065
  • The block which was specified by the address P in the block which includes a G71, G72 or G73 command does not include a G00 or G01 command.
  • In G71 and G72, Z (W) has been commanded (G71) or X (U) has been commanded (G72) in the block of sequence No. commanded by P.
066One of the G codes other than G00, G01, G02, G03 or G04 was commanded between two blocks specified by addresses P or Q respectively in the block which includes the G70, G71 or G72 command.
067Either G70, G71, G72 or G73 was commanded in the tape mode or the MDI mode. (G70, G71, G72 or G73 command is effective only in MEMORY mode.)
069The final transfer command in the blocks sandwiched between two blocks specified by P and Q of G71, G72 and G73 has ended with chamfering or corner R.
070The memory is insufficient.
071The address to be searched was not found.
072The number of programs to be stored exceeds 95 or 191.
073The program number has already been used.
074The program number is other than 1 - 9999.
075The program number and sequence number was not found at the start block of the program.
076The address P was not commanded in the block which includes a M98, G65 or G66 command.
077The subprogram was called in triple (Quintet with user macro option).
078The program number (specified program number in the case of call by G, M or T) or the sequence number which was specified by address P in the block which includes a M98, M99, G65, G66 and call by G, M or T was not found.
079Momorized program and tape contents do not coincide. (Collating program)
080In the area specified by parameter , the approach end signal does not come ON. (Automatic tool compensation function)
081Automatic tool compensation has been commanded without T code. (Automatic tool compensation function)
082T code and automatic tool compensation have been commanded in the same block. (Automatic tool compensation function)
083In automatic tool compensation, an invalid axis has been specified or the command is of incremental. (Automatic tool compensation function)
085In reading by RS-232C interface, the number of bits of input data does not match or baud rate is not correct.
086In reading or in output by RS-232C interface, transmission or I/O device trouble occurs.
087In reading by RS-232C interface, after DC3 (stop code) is transmitted, data over 10 characters long is input.
088The data erroe signal (DERR) has been input. (External input tool compensation function A)
089BCD data is not 0-9. (External input tool compensation function A)
090The reference point return cannot be performed normally because one revolution signal is not input from the position coder.
091Reference point return cannot be executed normally, because the feed rate is too low to synchronize the one-revolution signal of the position coder with the reference number
092The axis commanded by a G27 has not yet returned to the reference point.
094No P type can be specified for program restart (because after program interruption, programming of absolute zero point, ORGIN, etc. have been operated for).
095No P type can be specified for program restart (because after program interruption, external zero offset value has changed).
096No P type can be specified for program restart (because after program interruption, work zero offset value has changed).
097No P type can be specified for program restart (because after power is turned on, no automatic operation has been executed).
100The parameter enable switch is on. Push the reset button after turning off the swicth.
101The power was turned off while rewriting the contents of memory in the part program storage & editing operation. When this alarm is generated, you must turn on the power while pushing the DELETE and RESET buttons to clear the memory.
110Absolute value of data of fixed point representation exceeds the upper bound.
111Exponent of data of floating point representation exceeds the upper bound.
112Divisor is 0 zero
113A function that cannot be used by user macro A is used.
114Format error except for <Format>
115Value not defined as variable number is assigned.
116Left side of substituted sentence is a variable of prohibited substitution.
118Nesting of brackets exceeds the upper limit (5).
119Argument of SQRT is negative. The argument in BCD is of negative value.
122Nesting of macro exceeds the upper limit (4).
123Macro control command is used in tape mode.
124DO - END is not 1 : 1 corresponding.
125Format error of <Formula>.
126Not 1 < N < 3 in DO n. [1 (less than or equal) n (less than or equal) 3]
127NC command and macro command are mixed.
128Not 0 < n < 9999 in GO TO n
129Unallowable address is used in <Argument assignment>.
130In external data input, greater-address data contains an error.
131In external alarm message, five or more alarms occur.
132In external alarm message clear, no corresponding alarm number exists.
133In external alarm message and in external operator message, smaller-address data contains an error
170Programs of numbers 8000-8999 and 9000-9899 are being edited. But this alarm occurs only when parameter setting inhibits these programs to be edited. (See parameters 318 - PRG9, and 319 - PRG8.)
210The movable part of machine has touched the X axis plus stroke limit.
211The movable part of machine has touched the X axis minus stroke limit.
212While the X axis is moving in the plus direction, is has entered into the forbidden area of the stored stroke limit 1.
213While the X axis is moving in the minus direction, is has entered into the forbidden area of the stored stroke limit 1.
214While the X axis is moving in the plus direction, is has entered into the forbidden area of the stored stroke limit 2 or 3.
215While the X axis is moving in the minus direction, is has entered into the forbidden area of the stored stroke limit 2 or 3.
220The movable part of machine has touched the Z axis plus stroke limit.
221The movable part of machine has touched the Z axis minus stroke limit.
222While the Z axis is moving in the plus direction, is has entered into the forbidden area of the stored stroke limit 1.
223While the Z axis is moving in the minus direction, is has entered into the forbidden area of the stored stroke limit 1.
224While the Z axis is moving in the plus direction, is has entered into the forbidden area of the stored stroke limit 2 or 3.
225While the Z axis is moving in the minus direction, is has entered into the forbidden area of the stored stroke limit 2 or 3.
400The control has received the X or Z axis overload signal.
401The READY signal (VRDY) of the velocity control has turned off.
404The READY signal (VRDY) of the velocity control does not turn off even though the READY signal (PRDY) of the position control has turned off. The READY signal (VRDY) of the velocity control turns on even though the READY signal (PRDY) of the position control has not turned on.
405The reference point return might not be performed correctly because of faults of NC or servo system. Re-try manual reference point return.
410The value of position deviation amount of the X axis is larger than the value allowed while the machine is stopped.
411The value of position deviation amount of the X axis is larger than the value allowed while the machine is moving.
412Drift amount on X axis is excessive. (Exceeds 500VELO)
413The value of position deviation amount of the X axis exceeded ±32767. Or the velocity command value of the DA converter is out of the range of +8191 to -8191. Incorrect settings will cause this alarm.
414Fault in the position detection system of resolver or inductosyn in the X axis.
415A feedrate exceeding 511875 detection unit/sec. was commanded in the X axis. An incorrect setting of CMR causes this error.
416The position detector of X axis pulse coder is faulty (burn-out alarm).
420The value of position deviation amount of the Z axis is larger than the value allowed while the machine is stopped.
421The value of position deviation amount of the Z axis is larger than the value allowed while the machine is moving.
422Drift amount on Z axis is excessive. (Exceeds 500VELO)
423The value of position deviation amount of the Z axis exceeded ±32767. Or the velocity command value of the DA converter is out of the range of +8191 to -8191. Incorrect settings will cause this alarm.
424Fault in the position detection system of resolver or inductosyn in the Z axis.
425A feedrate exceeding 511875 detection unit/sec. was commanded in the Z axis. An incorrect setting of CMR causes this error.
426The position detector of Z axis pulse coder is faulty (burn-out alarm).
600Data transferring error takes place in the connection unit or in PC model C
601Slave ready has turned off.
602PC program has not yet been loaded.
603The correspondence between NC and PC is incorrect or interrupted.
604No hold is effective to PC model B-side MPU.
605A system error occurs in PC model B-side MPU (watch dog timer alarm).
606RAM/ROM parity error occurs in PC model B-side MPU.
607Data transferring error occurs in MDI & CRT.
700Overheat in the main PCB.
702Overheat of DC motor.

- Errors Numbered 900 and higher are NC Errors -

900Fault in bubble device (fault of input signal for bubble device).
901Fault in bubble device (the initial point in the bubble was not detected immediately after power on).
902Fault in bubble device (page size error, indefinde command).
903Fault in bubble device (transfer missing).
904Fault in bubble device (parity error).
905Fault in bubble device (no marker).
906Fault in bubble device (many defect loops).
910Ram parity error (low byte).
911Ram parity error (high byte).
920System error (watch dog timer alarm).
930CPU error (0,3,4, type interrupt generation).
940Memory error for offset value (abnormally large offset value set). Set a correct value to the specified offset number.
997ROM parity error (PC ROM).
998ROM parity error (Basic ROM).
999ROM pair error (no correspondence between high and low).